PFC 150×75×18 (BS 4-1:2005)

Source: SCI Blue Book (BS EN 10365:2017). Verified fields: A, G, It, Iw, Iy, Iz, Wply, Wplz, Wy, Wz, b, h, iy, iz, r, tf, tw. Other fields remain unverified unless identified as calculated.

h = 150 mm · b = 75 mm · tw = 5.5 mm · tf = 10 mm · G = 17.9 kg/m

BS 4-1:2005 Channel section
Cross-Section Profile — PFC 150×75×18 (to scale)

All dimensions in mm · Channel section · G = 17.9 kg/m · BS 4-1:2005

17.9
kg / m
22.8
A (cm²)
861
Iy (cm⁴)
115
Wy (cm³)

Reference values — verify against the current edition of the applicable standard or manufacturer's table before design use.

Section Properties

Overall depth h 150 mm
Width b 75 mm
Web thickness tw 5.5 mm
Flange thickness tf 10 mm
Root radius r 12 mm
Area A 22.8 cm²
Mass per length G 17.9 kg/m
Second moment (y-y) Iy 861 cm⁴
Elastic modulus (y-y) Wy 115 cm³
Plastic modulus (y-y) Wpl,y 132 cm³
Radius (y-y) iy 6.15 cm
Second moment (z-z) Iz 131 cm⁴
Elastic modulus (z-z) Wz 26.6 cm³
Plastic modulus (z-z) Wpl,z 47.2 cm³
Radius (z-z) iz 2.4 cm
Torsion constant It 6.1 cm⁴
Warping constant Iw 4670 cm⁶

Using this section record

Read the axis labels before using inertia or modulus: the major and minor axes are not interchangeable. Dimensions are in millimetres; area is in cm², second moments in cm⁴, moduli in cm³ and radii in cm. Convert powers of length consistently when transferring values to a calculation.

A Source line covers only its listed verified fields. Other fields remain subject to verification. A dash is unavailable, never zero. Withheld values must not be inferred from the remaining dimensions. Nominal mass and dimensions are reference values rather than measured tolerances or procurement guarantees. Confirm the exact product, manufacturing route, grade and thickness with the manufacturer. Section properties alone do not establish member resistance: stability, effective length, connections and project design requirements need separate assessment.