UB 610×229×113 (BS 4-1:2005)

Source: SCI Blue Book (BS EN 10365:2017). Verified fields: A, G, It, Iw, Iy, Iz, Wply, Wplz, Wy, Wz, b, h, iy, iz, r, tf, tw. Other fields remain unverified unless identified as calculated.

h = 607.6 mm · b = 228.2 mm · tw = 11.1 mm · tf = 17.3 mm · G = 113 kg/m

BS 4-1:2005 I/H section
Cross-Section Profile — UB 610×229×113 (to scale)

All dimensions in mm · I/H section · G = 113 kg/m · BS 4-1:2005

113
kg / m
144
A (cm²)
87300
Iy (cm⁴)
2870
Wy (cm³)

Reference values — verify against the current edition of the applicable standard or manufacturer's table before design use.

Section Properties

Overall depth h 607.6 mm
Width b 228.2 mm
Web thickness tw 11.1 mm
Flange thickness tf 17.3 mm
Root radius r 12.7 mm
Area A 144 cm²
Mass per length G 113 kg/m
Second moment (y-y) Iy 87300 cm⁴
Elastic modulus (y-y) Wy 2870 cm³
Plastic modulus (y-y) Wpl,y 3280 cm³
Radius (y-y) iy 24.6 cm
Second moment (z-z) Iz 3430 cm⁴
Elastic modulus (z-z) Wz 301 cm³
Plastic modulus (z-z) Wpl,z 469 cm³
Radius (z-z) iz 4.88 cm
Torsion constant It 111 cm⁴
Warping constant Iw 2990000 cm⁶

Using this section record

Read the axis labels before using inertia or modulus: the major and minor axes are not interchangeable. Dimensions are in millimetres; area is in cm², second moments in cm⁴, moduli in cm³ and radii in cm. Convert powers of length consistently when transferring values to a calculation.

A Source line covers only its listed verified fields. Other fields remain subject to verification. A dash is unavailable, never zero. Withheld values must not be inferred from the remaining dimensions. Nominal mass and dimensions are reference values rather than measured tolerances or procurement guarantees. Confirm the exact product, manufacturing route, grade and thickness with the manufacturer. Section properties alone do not establish member resistance: stability, effective length, connections and project design requirements need separate assessment.